Warning
The mixture is classified as hazardous according to regulation (EC) No 1272/2008 [CLP].
UFI-Code: W300-P0FG-F00G-GRTP
H226Flammable liquid and vapour.
H336 May cause drowsiness or dizziness.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P243 Take action to prevent static discharges.
P261 Avoid breathing vapours.
P271 Use only outdoors or in a well-ventilated area.
P280 Wear protective gloves and eye/face protection.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P312 Call a POISON CENTER or doctor/physician if you feel unwell.
P370 + P378 In case of fire: Use extinguishing powder or sand to extinguish.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P403 + P235 Store in a well-ventilated place. Keep cool.
P405 Keep locked up.
Our Schraubensicherungslack Standard (torque sealant) is the essential tool to protect, mark, fill and seal work involving all kinds of screw securing jobs.
White
Yellow
Red
Blue
Green
Grey
Black
Orange
Pink
Transparent
Torque sealant is used as a torque loosening indicator to immediately detect loosening of safety-related fasteners.
Torque sealant is used as a visual inspection marker to indicate that a bolted joint has already been properly tightened or any other workpiece has been inspected/approved.
Torque sealant is used as a tamper indicator to indicate whether threaded connections or components have been loosened without authorization.
Torque sealant is used as an assignment indicator to indicate which point in the production chain (e.g., production, installation, maintenance etc.) worked last on the workpiece at hand.
Viscosity | 15.000 - 20.000 mPas |
VOC content | 540 g/L ±20 g/L* |
Application temperature | +5 - 30° C |
Temperature stability | up till 125° C |
pH value | - |
Flashpoint | 29° C |
Touch dry after | ca. 5 min** |
Fully hardened after | ca. 24 hours** |
Density | ca. 1,05 g/cm3 |
Water | |
Gasoline | |
Super 95 | |
White spirit 135/175 | |
Special boiling point product 100/140 | |
Ethanol | |
Isopropyl alcohol (IPA) | |
n-Butanol | |
2‑Methoxy-1-Propanol | |
Butylacetate | |
Ethylacetate | |
Acetone | |
Methyl ethyl ketone (MEK) | |
Titanium grease | |
WD-40 | |
Hydrochloric acid 0,5 mol/l | |
Hydrofluorether |
The mixture is classified as not hazardous according to regulation (EC) No 1272/2008 [CLP].
not applicable
not applicable
Schraubensicherungslack Zero (aqueous torque sealant) from Lackfabrik Bäder GmbH & Co. KG is the first 100% water-based securing lacquer system that works completely without organic solvents (VOC-free).
White
Yellow
Red
Blue
Green
Grey
Black
Neon Orange
Torque sealant is used as a torque loosening indicator to immediately detect loosening of safety-related fasteners.
Torque sealant is used as a visual inspection marker to indicate that a bolted joint has already been properly tightened or any other workpiece has been inspected/approved.
Torque sealant is used as a tamper indicator to indicate whether threaded connections or components have been loosened without authorization.
Torque sealant is used as an assignment indicator to indicate which point in the production chain (e.g., production, installation, maintenance etc.) worked last on the workpiece at hand.
Viscosity | 20.000 - 30.000 mPas |
VOC content | 0 g/L |
Application temperature | +5 - 30° C |
Temperature stability | up till 90° C |
pH value | ca. 8 - 9 |
Flashpoint | - |
Touch dry after | ca. 10 min* |
Fully hardened after | ca. 4 hours* |
Density | ca. 0,98 g/cm3 |
Water | |
Gasoline | |
Super 95 | |
White spirit 135/175 | |
Special boiling point product 100/140 | |
Ethanol | |
Isopropyl alcohol (IPA) | |
n-Butanol | |
2‑Methoxy-1-Propanol | |
Butylacetate | |
Ethylacetate | |
Acetone | |
Methyl ethyl ketone (MEK) | |
Titanium grease | |
WD-40 | |
Hydrochloric acid 0,5 mol/l | |
Hydrofluorether |
Danger
The mixture is classified as hazardous according to regulation (EC) No 1272/2008 [CLP].
UFI-Code: P600-604V-S000-53DR
H226Flammable liquid and vapour.
H319Causes serious eye irritation.
H336 May cause drowsiness or dizziness.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P243 Take action to prevent static discharges.
P261 Avoid breathing vapours.
P264 Nach Gebrauch Hände gründlich waschen.
P271 Use only outdoors or in a well-ventilated area.
P280 Wear protective gloves and eye/face protection.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower].
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P312 Call a POISON CENTER or doctor/physician if you feel unwell.
P337 + P313 If eye irritation persists: Get medical advice/attention.
P370 + P378 In case of fire: Use extinguishing powder or sand to extinguish.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P403 + P235 Store in a well-ventilated place. Keep cool.
P405 Keep locked up.
The Schraubensicherungslack Fast Dry from Lackfabrik Bäder GmbH & Co. KG is an extremely fast drying torque sealant (tamper proof sealant), which is characterized by an excellent anti-flow behavior and good adhesion properties.
White
Yellow
Red
Blue
Green
Grey
Black
Orange
Pink
Torque sealant is used as a torque loosening indicator to immediately detect loosening of safety-related fasteners.
Torque sealant is used as a visual inspection marker to indicate that a bolted joint has already been properly tightened or any other workpiece has been inspected/approved.
Torque sealant is used as a tamper indicator to indicate whether threaded connections or components have been loosened without authorization.
Torque sealant is used as an assignment indicator to indicate which point in the production chain (e.g., production, installation, maintenance etc.) worked last on the workpiece at hand.
Viscosity | 20.000 - 30.000 mPas |
VOC content | 520 g/L ±20 g/L* |
Application temperature | +5 - 30° C |
Temperature stability | up till 125° C |
pH value | - |
Flashpoint | -4° C |
Touch dry after | ca. 30 - 45 s** |
Fully hardened after | ca. 24 hours** |
Density | ca. 1,05 g/cm3 |
Water | |
Gasoline | |
Super 95 | |
White spirit 135/175 | |
Special boiling point product 100/140 | |
Ethanol | |
Isopropyl alcohol (IPA) | |
n-Butanol | |
2‑Methoxy-1-Propanol | |
Butylacetate | |
Ethylacetate | |
Acetone | |
Methyl ethyl ketone (MEK) | |
Titanium grease | |
WD-40 | |
Hydrochloric acid 0,5 mol/l | |
Hydrofluorether |